For Houston owners
A plan for meeting Houston's AC rule, room by room, before the deadline.
Comply by
Five steps
- 1
List every habitable room
Each room used for living, sleeping, eating, or cooking needs cooling. Bathrooms, toilet rooms, closets, halls, storage rooms, and utility rooms don't.
- 2
Test what's already there
Existing cooling counts if it can keep the room 20°F cooler than outside, or at 80°F or below, and is in good operating condition. Equipment that met the Construction Code when installed is acceptable if it still works and is safe.
- 3
Choose equipment for the rest
Central air isn't required. Window units, portable units, central air, or other refrigerated equipment all count if they meet the standard.
- 4
Size each room
The code sets a temperature standard, not a unit size. The ENERGY STAR chart below is a common starting point for room units.
- 5
Install, and keep moving
Until December 17, 2026, the code expects reasonable and continuous progress. Keeping dated receipts and work orders is a simple way to show it.
Room unit sizing (ENERGY STAR)
For rooms with 8 foot ceilings.
Room size
BTU per hour- 100 to 150 sq ft
- 5,000
- 150 to 250 sq ft
- 6,000
- 250 to 300 sq ft
- 7,000
- 300 to 350 sq ft
- 8,000
- 350 to 400 sq ft
- 9,000
- 400 to 450 sq ft
- 10,000
- 450 to 550 sq ft
- 12,000
- 550 to 700 sq ft
- 14,000
- 700 to 1,000 sq ft
- 18,000
- 1,000 to 1,200 sq ft
- 21,000
- 1,200 to 1,400 sq ft
- 23,000
- 1,400 to 1,500 sq ft
- 24,000
- 1,500 to 2,000 sq ft
- 30,000
- 2,000 to 2,500 sq ft
- 34,000
- Heavily shaded roomReduce capacity by 10%.
- Very sunny roomIncrease capacity by 10%.
- More than two regular occupantsAdd 600 BTU for each extra person.
- KitchenAdd 4,000 BTU.
Who can install it
- Central and ducted systemsIn Texas, air conditioning contracting work requires a state contractor license. In Houston, changing an existing system by adding or removing equipment also takes a City mechanical permit, pulled by a contractor whose license is registered with the City.
- Portable and self contained unitsThe state license law doesn't apply to portable or self contained ductless units of three tons (36,000 BTU) or less.
- Your own maintenance staffThe license law doesn't apply to a regular maintenance employee of the owner or management company, working on that company's property, when neither does AC contracting for the public.
- Your own homeThe license law doesn't apply to work on a home you own alone and live in.
If a tenant reports it
- Inspection firstA 311 complaint sends a city inspector, and owners get a chance to fix the problem.
- CitationsA criminal citation comes only after a written warning and a reasonable chance to cure. The City can also issue an administrative citation or summons.
- FinesA misdemeanor, $200 to $2,000 on conviction, with each day a separate offense.
- DefensesNew construction making reasonable and continuous progress; utilities lawfully cut for nonpayment where the tenant didn't pay the utility directly and the unit otherwise substantially complied; or a violation that reasonable investigation or inspection couldn't have found.
- Leases and retaliationA lease can't excuse compliance, and owners and managers can't retaliate against a resident for reporting. What tenants can do